Welcome to the GEMA Shop – your expert for heating, solar, and plumbing technology since 1991. We provide personal consultation and offer technical solutions.
  • fast shipping

  • Free help and advice

  • Open 7 days a week

+49 (0)39262 8787 - 20/21/23/12 *** sales@gema-net.de *** WhatsApp. +49(0)17660429928

Atmos  |  SKU: 01.12.16

ATMOS KC16S coal gasification boiler 18 kW

Coal gasification boiler designed for lignite briquettes with 18 kW output

Rotary grate mechanism and ceramic-lined combustion chamber for gasifier operation

Induced draft fan to support low-smoke refueling

The ATMOS KC16S coal gasifier is a manually loaded hot water boiler for lignite briquettes with 18 kW output and wood as an alternative fuel. It is suitable for family homes and similar properties and operates with a ceramic-lined combustion chamber, rotating grate mechanism, and exhaust fan.

Normal price 3.776,13 €
vAT included. Shipment will be charged at checkout.


Name: Jaroslav Cankař a syn ATMOS

Address: elenského 487 294 21 Bělá pod Bezdězem, Cr

Email: info@atmos-zentrallager.de

Website: https://www.atmos.eu/de/

European Manufacturer: Yes

Highlights

Rated output 18 kW
Efficiency 88,5 %
Chimney draft 16 Pa
Max. operating pressure 2,5 bar
Max. log length 230 mm

Equipped with a cooling loop to prevent overheating

Separate adjustment of primary and secondary air

Control via boiler thermostat, flue gas thermostat and safety thermostat

Cleaning accessories, ash container and Honeywell FR124 included in delivery

Designed for family homes, weekend houses and similar properties

Description

Product Overview & Application

The ATMOS KC16S coal gasifier is a manually fed hot water boiler designed for lignite briquettes and intended for heating family homes, weekend houses, and similar properties. The model operates with a boiler heat output of 18 kW and can also use dry split logs as an alternative fuel. This makes the boiler suitable for operators looking for a robust solid fuel boiler with classic manual feeding and water-based integration.

Technology & Equipment

The boiler body is a welded steel construction and operates on the principle of downdraft gasification with an induced draft fan. Ceramic moldings are used in the lower combustion chamber, while the rotating grate mechanism with secondary air supply supports combustion and facilitates ash removal. The equipment includes a thermometer, boiler thermostat, flue gas thermostat, safety thermostat, and a cooling loop to prevent overheating. Primary and secondary air can be adjusted separately, allowing adaptation to the fuel and operating conditions.

Everyday Advantages

In daily operation, the KC16S scores with clear, mechanically straightforward boiler technology. The induced draft fan helps reduce smoke when refueling, and the grate mechanism aids in removing ash during operation. For the user, this means straightforward operation with robust technology, easily accessible cleaning areas, and a design tailored for classic use with lignite briquettes.

System Integration & Compatibility

The boiler is designed for integration into a water-based heating system and requires a professionally designed chimney as well as a boiler room with an adequate combustion air supply. The documentation specifies a minimum required return temperature of 65 °C and a boiler operating range of 80 to 90 °C. For low-corrosion operation, the manufacturer describes integration with return temperature boosting, e.g., via a Laddomat 22 or a suitable thermostatic control valve; additionally, combining it with buffer tanks is described as a sensible system solution.

Technical Data at a Glance

The key confirmed specifications of the ATMOS KC16S in a compact overview.

Rated Output 18 kW
Fuel Lignite briquettes
Combustion Technology Downdraft gasification with induced draft fan
Efficiency 88.5 %
Energy Efficiency Class C
Max. Operating Pressure 2.5 bar
Boiler Class 5
Required Chimney Draft 16 Pa
Flue Gas Temperature at Rated Output 165 °C
Flue Pipe Connection 150/152 mm
Max. Log Length 230 mm
Height 1166 mm
Width 675 mm
Depth 658 mm
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W
Weight 275 kg

Installation

Installation must be planned for a boiler room with adequate combustion air; the manual specifies an opening of at least 300 cm² for systems from 15 to 75 kW. The connection to the chimney, flue duct, heating system, and power supply must be carried out professionally. For operation, return temperature boosting and protection against overheating must be considered; the manufacturer also recommends a concrete or steel foundation under the boiler.

Notes

The KC16S is designed for lignite briquettes; dry split logs serve as an alternative fuel. During operation, doors, covers, and the start-up flap must be operated in the intended position, and the boiler must be cleaned regularly to maintain performance and service life. The documentation also specifies an annual technical inspection of the boiler room and exhaust system, as well as a CE declaration of conformity for the series.

Scope of Delivery

  • ATMOS KC16S coal gasification boiler
  • Steel brush with accessories
  • Poker
  • Filling valve
  • Operating and maintenance manual
  • Honeywell FR 124 draft regulator
  • Ash container

payment & Security

Payment options

  • American Express
  • Apple Pay
  • Bancontact
  • BLIK
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store or access your credit card information.

Contact us