{"product_id":"viallant-warmepumpe-arotherm-plus","title":"Vaillant heat pump aroTHERM plus","description":"\u003cdiv class=\"base__image-text-section overflow-auto\"\u003e  \u003cdiv class=\"base__image-text-section__container\"\u003e  \u003ch2\u003eVaillant aroTHERM plus heat pump\u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003eThe Vaillant air\/water heat pump is as compact as it is effective.\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eOur aroTHERM plus is an outdoor air-to-water heat pump in a monobloc design, requiring only 0.5 m² of floor space. Heat is generated in the outdoor unit and transferred via supply lines to the indoor unit in the boiler room. The aroTHERM plus is perfectly complemented by an indoor hydraulic unit, such as our uniTOWER plus hydraulic tower. With its integrated 185-liter storage tank, this easily covers the hot water needs of a family of four. For higher hot water demands, our wall-mounted hydraulic station and a suitable hot water storage tank are ideal.\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cdiv class=\"content-toggle-group content-toggle-group--theme-expand content-toggle--is-deactivated\" data-content-toggle-theme-activated-only=\"default\" data-content-toggle-deactivate-at-breakpoint=\"640\"\u003e  \u003ch3 class=\"content-toggle\"\u003eModernize for the future\u003c\/h3\u003e  \u003c\/div\u003e  \u003cdiv class=\"content-toggle\"\u003e  \u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent1\" aria-labelledby=\"benefitTrigger1\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cp\u003eBecause the aroTHERM plus uses the natural refrigerant R290, its 7–12 kW output makes it ideal for climate-conscious modernization projects. Replacing old oil or gas heating systems in single-family homes is no problem. The refrigerant allows for high flow temperatures in heat pump operation, so existing radiators can also be used. Another advantage: R290 has a very low global warming potential. With a COP of up to 3.3 and 3.8, our aroTHERM plus also operates very efficiently and in an environmentally friendly manner. Alternatively, it can also be installed in new buildings.\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003ch3 class=\"content-toggle\"\u003eThe quietest heat pump in its class\u003c\/h3\u003e  \u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" aria-labelledby=\"benefitTrigger2\"\u003e  \u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" aria-labelledby=\"benefitTrigger2\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cp\u003eThe integrated Sound Safe System ensures that the aroTHERM plus operates particularly quietly. This makes it ideal for use even in densely populated areas, such as terraced housing developments. In night mode, the sound power level is only 46 dB(A), and at a distance of 3 meters, it is just 29 dB(A). This means the aroTHERM plus easily falls below the noise limits set by the German Technical Instructions on Noise Protection (TA-Lärm) in densely populated residential areas.\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eImportant instructions!\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eRequires multiMATIC 700 or sensoCOMFORT 720. An additional coding resistor is required for active cooling operation.\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003ch3\u003eProduct features:\u003cbr\u003e\u003cbr\u003e  \u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eModulating EC fan\u003c\/li\u003e  \u003cli\u003eHigh-efficiency pump\u003c\/li\u003e  \u003cli\u003eSensor-controlled refrigeration circuit\u003c\/li\u003e  \u003cli\u003eIntegrated R290 safety concept\u003c\/li\u003e  \u003cli\u003eAutomatic air vent valve\u003c\/li\u003e  \u003cli\u003eCooling operation can be activated with a coding plug (the heating system must be prepared on-site for this)\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003e  \u003cbr\u003eSpecial features:\u003cbr\u003e\u003cbr\u003e  \u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eHigh flow temperatures for modernization\u003c\/li\u003e  \u003cli\u003eModulating compressor with inverter technology constantly adjusts the output to the current building heating load.\u003c\/li\u003e  \u003cli\u003eSoundSafeSystem for particularly quiet operation\u003c\/li\u003e  \u003cli\u003eCan also be integrated into an existing heating system\u003c\/li\u003e  \u003cli\u003eThe hybrid system can be operated bivalently, alternatively, in parallel, or with the triVAI parameter.\u003c\/li\u003e  \u003cli\u003eIntelligent use of self-generated energy (PVready)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003e\u003c\/p\u003e  \u003ch3\u003e  \u003cstrong\u003eScope of delivery: \u003c\/strong\u003eVaillant aroTHERM plus heat pump\u003c\/h3\u003e  \u003cp\u003e\u003cbr\u003e1 aroTHERM VWL\u003cbr\u003e1 Condensate drain\u003cbr\u003e1 bag of seals\u003cbr\u003e1 vent hose\u003cbr\u003e1 Operating and installation instructions\u003cbr\u003e1 Product data sheet, energy efficiency label\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003c\/div\u003e  \u003ch3\u003eTechnical data: Vaillant aroTHERM plus heat pump\u003c\/h3\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cstyle type=\"text\/css\"\u003e\n\ttable.tableizer-table {\n\t\tfont-size: 12px;\n\t\tborder: 1px solid #CCC; \n\t\tfont-family: Arial, Helvetica, sans-serif;\n\t} \n\t.tableizer-table td {\n\t\tpadding: 4px;\n\t\tmargin: 3px;\n\t\tborder: 1px solid #CCC;\n\t}\n\t.tableizer-table th {\n\t\tbackground-color: #104E8B; \n\t\tcolor: #FFF;\n\t\tfont-weight: bold;\n\t}\n\u003c\/style\u003e  \u003cdiv class=\"content-toggle__content\" aria-hidden=\"false\" role=\"tabpanel\" id=\"benefitContent2\" aria-labelledby=\"benefitTrigger2\"\u003e  \u003ctable class=\"tableizer-table\"\u003e  \u003cthead\u003e  \u003ctr class=\"tableizer-firstrow\"\u003e  \u003cth\u003e\u003c\/th\u003e  \u003cth\u003eVWL 35\/6 A\u003c\/th\u003e  \u003cth\u003eEconomics 55\/6 A\u003c\/th\u003e  \u003cth\u003eVWL 75\/6 A\u003c\/th\u003e  \u003cth\u003eEconomics 105\/6 A\u003c\/th\u003e  \u003cth\u003eEconomics 125\/6 A\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody\u003e  \u003ctr\u003e  \u003ctd\u003eEnergy efficiency class 55°C (A+++ - D)\u003c\/td\u003e  \u003ctd\u003eA+\u003c\/td\u003e  \u003ctd\u003eA++\u003c\/td\u003e  \u003ctd\u003eA++\u003c\/td\u003e  \u003ctd\u003eA++\u003c\/td\u003e  \u003ctd\u003eA++\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eEnergy efficiency class 35°C (A+++ - D)\u003c\/td\u003e  \u003ctd\u003eA++\u003c\/td\u003e  \u003ctd\u003eA+++\u003c\/td\u003e  \u003ctd\u003eA+++\u003c\/td\u003e  \u003ctd\u003eA+++\u003c\/td\u003e  \u003ctd\u003eA+++\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output\/Electrical output\/COP at A-7\/W35\u003c\/td\u003e  \u003ctd\u003e3.6 kW\/1.55 kW\/2.2\u003c\/td\u003e  \u003ctd\u003e5.4 kW\/2.08 kW\/2.6\u003c\/td\u003e  \u003ctd\u003e7.0 kW\/2.5 kW\/2.8\u003c\/td\u003e  \u003ctd\u003e9.2 kW\/3.41 kW\/2.7\u003c\/td\u003e  \u003ctd\u003e12.2 kW\/4.52 kW\/2.7\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output\/Electrical output\/COP at A2\/W35\u003c\/td\u003e  \u003ctd\u003e2.0 kW\/0.51 kW\/3.9\u003c\/td\u003e  \u003ctd\u003e2.0 kW\/0.51 kW\/3.9\u003c\/td\u003e  \u003ctd\u003e3.1 kW\/0.76 kW\/4.1\u003c\/td\u003e  \u003ctd\u003e5.8 kW\/1.26 kW\/4.6\u003c\/td\u003e  \u003ctd\u003e5.9 kW\/1.28 kW\/4.6\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output\/Electrical output\/COP at A7\/W35\u003c\/td\u003e  \u003ctd\u003e3.3 kW\/0.69 kW\/4.8\u003c\/td\u003e  \u003ctd\u003e3.4 kW\/0.71 kW\/4.8\u003c\/td\u003e  \u003ctd\u003e4.6 kW\/0.96 kW\/4.8\u003c\/td\u003e  \u003ctd\u003e8.1 kW\/1.53 kW\/5.3\u003c\/td\u003e  \u003ctd\u003e8.5 kW\/1.57 kW\/5.4\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output\/Electrical output\/COP at A10\/W35\u003c\/td\u003e  \u003ctd\u003e3.4 kW\/0.64 kW\/5.3\u003c\/td\u003e  \u003ctd\u003e3.5 kW\/0.66 kW\/5.3\u003c\/td\u003e  \u003ctd\u003e4.8 kW\/0.92 kW\/5.2\u003c\/td\u003e  \u003ctd\u003e8.7 kW\/1.53 kW\/5.3\u003c\/td\u003e  \u003ctd\u003e8.8 kW\/1.54 kW\/5.7\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCooling capacity\/Electrical power\/EER at A35\/W18\u003c\/td\u003e  \u003ctd\u003e4.5 kW\/1.05 kW\/4.3\u003c\/td\u003e  \u003ctd\u003e4.5 kW\/1.05 kW\/4.3\u003c\/td\u003e  \u003ctd\u003e6.4 kW\/1.52 kW\/4.2\u003c\/td\u003e  \u003ctd\u003e10.9 kW\/2.37 kW\/4.6\u003c\/td\u003e  \u003ctd\u003e10.8 kW\/2.35 kW\/4.6\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eSeasonal space heating efficiency ηS at 35°C\u003c\/td\u003e  \u003ctd\u003e174%\u003c\/td\u003e  \u003ctd\u003e181%\u003c\/td\u003e  \u003ctd\u003e182%\u003c\/td\u003e  \u003ctd\u003e196%\u003c\/td\u003e  \u003ctd\u003e193%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eSeasonal space heating efficiency ηS at 55°C\u003c\/td\u003e  \u003ctd\u003e123%\u003c\/td\u003e  \u003ctd\u003e129%\u003c\/td\u003e  \u003ctd\u003e133%\u003c\/td\u003e  \u003ctd\u003e141%\u003c\/td\u003e  \u003ctd\u003e146%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCompressor power supply\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz, 1\/N\/PE~\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz, 1\/N\/PE~\u003c\/td\u003e  \u003ctd\u003e400 V\/50 Hz, 3\/N\/PE~\u003c\/td\u003e  \u003ctd\u003e400 V\/50 Hz, 3\/N\/PE~\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectricPump power consumption at min\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e3 W\u003c\/td\u003e  \u003ctd\u003e3 W\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectrical power consumption of pump (max)\u003c\/td\u003e  \u003ctd\u003e50 W\u003c\/td\u003e  \u003ctd\u003e50 W\u003c\/td\u003e  \u003ctd\u003e50 W\u003c\/td\u003e  \u003ctd\u003e87 W\u003c\/td\u003e  \u003ctd\u003e87 W\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eContents on the heating side\u003c\/td\u003e  \u003ctd\u003e1.5 l\u003c\/td\u003e  \u003ctd\u003e1.5 l\u003c\/td\u003e  \u003ctd\u003e2.0 l\u003c\/td\u003e  \u003ctd\u003e2.5 l\u003c\/td\u003e  \u003ctd\u003e2.5 l\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMax. operating pressure on the heating side\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating temperature (min.-max.)\u003c\/td\u003e  \u003ctd\u003e22-75 °C\u003c\/td\u003e  \u003ctd\u003e22-75 °C\u003c\/td\u003e  \u003ctd\u003e22-75 °C\u003c\/td\u003e  \u003ctd\u003e22-75 °C\u003c\/td\u003e  \u003ctd\u003e22-75 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHot water temperature with auxiliary heating (max.)\u003c\/td\u003e  \u003ctd\u003e75 °C\u003c\/td\u003e  \u003ctd\u003e75 °C\u003c\/td\u003e  \u003ctd\u003e75 °C\u003c\/td\u003e  \u003ctd\u003e75 °C\u003c\/td\u003e  \u003ctd\u003e75 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMaximum power consumption\u003c\/td\u003e  \u003ctd\u003e3.4 kW\u003c\/td\u003e  \u003ctd\u003e3.4 kW\u003c\/td\u003e  \u003ctd\u003e3.4 kW\u003c\/td\u003e  \u003ctd\u003e8.0 kW\u003c\/td\u003e  \u003ctd\u003e8.0 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eStarting current\u003c\/td\u003e  \u003ctd\u003e14.3 A\u003c\/td\u003e  \u003ctd\u003e14.3 A\u003c\/td\u003e  \u003ctd\u003e15 A\u003c\/td\u003e  \u003ctd\u003e15 A\u003c\/td\u003e  \u003ctd\u003e15 A\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ePump flow rate at 5K (residual delivery head)\u003c\/td\u003e  \u003ctd\u003e580 l\/h (780 mbar)\u003c\/td\u003e  \u003ctd\u003e580 l\/h (780 mbar)\u003c\/td\u003e  \u003ctd\u003e790 l\/h (640 mbar)\u003c\/td\u003e  \u003ctd\u003e1418 l\/h (788 mbar)\u003c\/td\u003e  \u003ctd\u003e1480 l\/h (730 mbar)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating connection (flow and return)\u003c\/td\u003e  \u003ctd\u003eG 1 1\/4\u003c\/td\u003e  \u003ctd\u003eG 1 1\/4\u003c\/td\u003e  \u003ctd\u003eG 1 1\/4\u003c\/td\u003e  \u003ctd\u003eG 1 1\/4\u003c\/td\u003e  \u003ctd\u003eG 1 1\/4\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eSound power level (A7\/W55)\u003c\/td\u003e  \u003ctd\u003e54 dB(A)\u003c\/td\u003e  \u003ctd\u003e54 dB(A)\u003c\/td\u003e  \u003ctd\u003e55 dB(A)\u003c\/td\u003e  \u003ctd\u003e59 dB(A)\u003c\/td\u003e  \u003ctd\u003e59 dB(A)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eProduct dimensions (height\/width\/depth)\u003c\/td\u003e  \u003ctd\u003e765\/1,100\/450 mm\u003c\/td\u003e  \u003ctd\u003e765\/1100\/450 mm\u003c\/td\u003e  \u003ctd\u003e965\/1100\/450 mm\u003c\/td\u003e  \u003ctd\u003e1,565\/1,100\/450 mm\u003c\/td\u003e  \u003ctd\u003e1565\/1100\/450 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eProduct weight\u003c\/td\u003e  \u003ctd\u003e114 kg\u003c\/td\u003e  \u003ctd\u003e114 kg\u003c\/td\u003e  \u003ctd\u003e128 kg\u003c\/td\u003e  \u003ctd\u003e210 kg\u003c\/td\u003e  \u003ctd\u003e210 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eRefrigerant quantity\u003c\/td\u003e  \u003ctd\u003e0.6 kg\u003c\/td\u003e  \u003ctd\u003e0.6 kg\u003c\/td\u003e  \u003ctd\u003e0.9 kg\u003c\/td\u003e  \u003ctd\u003e1.3 kg\u003c\/td\u003e  \u003ctd\u003e1.3 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eRefrigerant (natural)\u003c\/td\u003e  \u003ctd\u003eR290\u003c\/td\u003e  \u003ctd\u003eR290\u003c\/td\u003e  \u003ctd\u003eR290\u003c\/td\u003e  \u003ctd\u003eR290\u003c\/td\u003e  \u003ctd\u003eR290\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eGlobal warming potential according to regulation (EU)\u003c\/td\u003e  \u003ctd\u003e3\u003c\/td\u003e  \u003ctd\u003e3\u003c\/td\u003e  \u003ctd\u003e3\u003c\/td\u003e  \u003ctd\u003e3\u003c\/td\u003e  \u003ctd\u003e3\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCO2 equivalent\u003c\/td\u003e  \u003ctd\u003e0.0018 t\u003c\/td\u003e  \u003ctd\u003e0.0018 t\u003c\/td\u003e  \u003ctd\u003e0.0027 t\u003c\/td\u003e  \u003ctd\u003e0.0039 t\u003c\/td\u003e  \u003ctd\u003e0.0039 t\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e","brand":"Vaillant","offers":[{"title":"VWL 75\/6 A S2","offer_id":47229499801948,"sku":"10021118","price":6504.65,"currency_code":"EUR","in_stock":true},{"title":"Economics 55\/6 A S2","offer_id":47229499769180,"sku":"10021117","price":5600.9,"currency_code":"EUR","in_stock":true},{"title":"VWL 35\/6 A S2","offer_id":47229499736412,"sku":"10021116","price":5108.51,"currency_code":"EUR","in_stock":true},{"title":"VWL 125\/6 A S2","offer_id":47229499867484,"sku":"10021122","price":10268.45,"currency_code":"EUR","in_stock":true},{"title":"VWL 105\/6 A S2","offer_id":47229499834716,"sku":"10021120","price":9054.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/vaillant-warmepumpe-arotherm-plus-3176332.jpg?v=1770693549","url":"https:\/\/si.gemashop.de\/products\/vaillant-heat-pump-arotherm-plus","provider":"GEMA Shop","version":"1.0","type":"link"}