{"product_id":"attack-slx-35-lambda-holzvergaser-35-kw","title":"Wood gasifier 35 kW ATTACK SLX 35 Lambda","description":"\u003cp data-start=\"327\" data-end=\"722\"\u003eThe \u003cstrong data-start=\"331\" data-end=\"355\"\u003eATTACK SLX 35 LAMBDA\u003c\/strong\u003e This is a high-performance wood gasifier with a nominal output of 35 kW and integrated lambda control for particularly precise and low-emission combustion of logs. It is ideally suited for larger single-family homes, apartment buildings, or buildings with increased heating requirements. The automatic air control ensures consistently high efficiency and convenient operation.\u003c\/p\u003e  \u003chr data-start=\"724\" data-end=\"727\"\u003e  \u003ch2 data-start=\"729\" data-end=\"753\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"755\" data-end=\"1100\"\u003e⭐  \u003cstrong data-start=\"757\" data-end=\"779\"\u003e35 kW nominal power\u003c\/strong\u003e – ideal for large living spaces\u003cbr data-start=\"811\" data-end=\"814\"\u003e⭐  \u003cstrong data-start=\"816\" data-end=\"844\"\u003eIntegrated lambda sensor\u003c\/strong\u003e – automatic combustion optimization\u003cbr data-start=\"883\" data-end=\"886\"\u003e⭐  \u003cstrong data-start=\"888\" data-end=\"915\"\u003eEfficiency up to 89.5%\u003c\/strong\u003e – efficient fuel utilization\u003cbr data-start=\"949\" data-end=\"952\"\u003e⭐  \u003cstrong data-start=\"954\" data-end=\"989\"\u003eCertified according to EN 303-5:2012\u003c\/strong\u003e – tested emission values\u003cbr data-start=\"1015\" data-end=\"1018\"\u003e⭐  \u003cstrong data-start=\"1020\" data-end=\"1063\"\u003eTurbulator system with cleaning lever\u003c\/strong\u003e – maintenance-friendly design\u003c\/p\u003e  \u003chr data-start=\"1102\" data-end=\"1105\"\u003e  \u003ch1 data-start=\"1107\" data-end=\"1148\"\u003eATTACK SLX 35 LAMBDA wood gasifier 35 kW\u003c\/h1\u003e  \u003ch2 data-start=\"1150\" data-end=\"1180\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1182\" data-end=\"1345\"\u003eThe ATTACK SLX 35 LAMBDA is a \u003cstrong data-start=\"1215\" data-end=\"1264\"\u003eHot water boiler for solid fuels (wood)\u003c\/strong\u003e with automatic air control via lambda sensor. It is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"1347\" data-end=\"1455\"\u003e  \u003cli data-start=\"1347\" data-end=\"1374\"\u003e  \u003cp data-start=\"1349\" data-end=\"1374\"\u003elarge detached houses\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1375\" data-end=\"1397\"\u003e  \u003cp data-start=\"1377\" data-end=\"1397\"\u003eApartment buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1398\" data-end=\"1420\"\u003e  \u003cp data-start=\"1400\" data-end=\"1420\"\u003eRenovation projects\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1421\" data-end=\"1455\"\u003e  \u003cp data-start=\"1423\" data-end=\"1455\"\u003eHeating systems with buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1457\" data-end=\"1531\"\u003ePreferred fuels are \u003cstrong data-start=\"1485\" data-end=\"1530\"\u003eLogs with a moisture content ≤ 25%\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"1533\" data-end=\"1536\"\u003e  \u003ch2 data-start=\"1538\" data-end=\"1559\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1561\" data-end=\"1704\"\u003eThe integrated lambda control continuously measures the residual oxygen content in the exhaust gas and automatically adjusts the air supply. This results in:\u003c\/p\u003e  \u003cul data-start=\"1706\" data-end=\"1852\"\u003e  \u003cli data-start=\"1706\" data-end=\"1757\"\u003e  \u003cp data-start=\"1708\" data-end=\"1757\"\u003eOptimized combustion quality and efficiency\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1758\" data-end=\"1791\"\u003e  \u003cp data-start=\"1760\" data-end=\"1791\"\u003eFuel consumption reduced\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1792\" data-end=\"1816\"\u003e  \u003cp data-start=\"1794\" data-end=\"1816\"\u003eEmissions minimized\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1817\" data-end=\"1852\"\u003e  \u003cp data-start=\"1819\" data-end=\"1852\"\u003estable performance values ​​achieved\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1854\" data-end=\"1938\"\u003eEven with fluctuating wood quality, combustion remains efficient and reliable.\u003c\/p\u003e  \u003chr data-start=\"1940\" data-end=\"1943\"\u003e  \u003ch2 data-start=\"1945\" data-end=\"1969\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cul data-start=\"1971\" data-end=\"2327\"\u003e  \u003cli data-start=\"1971\" data-end=\"2015\"\u003e  \u003cp data-start=\"1973\" data-end=\"2015\"\u003eBoiler type: Wood gasification hot water boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2016\" data-end=\"2035\"\u003e  \u003cp data-start=\"2018\" data-end=\"2035\"\u003ePower: 35 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2036\" data-end=\"2083\"\u003e  \u003cp data-start=\"2038\" data-end=\"2083\"\u003eLambda sensor for automatic air control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2084\" data-end=\"2122\"\u003e  \u003cp data-start=\"2086\" data-end=\"2122\"\u003eFan-assisted combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2123\" data-end=\"2160\"\u003e  \u003cp data-start=\"2125\" data-end=\"2160\"\u003eTurbulators in the tube heat exchanger\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2161\" data-end=\"2204\"\u003e  \u003cp data-start=\"2163\" data-end=\"2204\"\u003eThermal safety device required\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2205\" data-end=\"2236\"\u003e  \u003cp data-start=\"2207\" data-end=\"2236\"\u003eMaximum operating pressure: 2.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2237\" data-end=\"2292\"\u003e  \u003cp data-start=\"2239\" data-end=\"2292\"\u003eMinimum chimney diameter: 150 mm (200 mm recommended)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2293\" data-end=\"2327\"\u003e  \u003cp data-start=\"2295\" data-end=\"2327\"\u003eRecommended chimney draft: 23–30 Pa\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2329\" data-end=\"2454\"\u003eTo ensure a long service life, a return temperature above 65 °C must be maintained. Recommended boiler temperature: 80–85 °C.\u003c\/p\u003e  \u003chr data-start=\"2456\" data-end=\"2459\"\u003e  \u003ch2 data-start=\"2461\" data-end=\"2482\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2484\" data-end=\"2595\"\u003eThe ATTACK SLX 35 LAMBDA meets the requirements of \u003cstrong data-start=\"2539\" data-end=\"2556\"\u003eEN 303-5:2012\u003c\/strong\u003e for boilers of fuel class A.\u003c\/p\u003e  \u003cp data-start=\"2597\" data-end=\"2630\"\u003eMeasurement values ​​according to the information sheet:\u003c\/p\u003e  \u003cul data-start=\"2632\" data-end=\"2781\"\u003e  \u003cli data-start=\"2632\" data-end=\"2662\"\u003e  \u003cp data-start=\"2634\" data-end=\"2662\"\u003eNominal heat output: 35.2 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2663\" data-end=\"2698\"\u003e  \u003cp data-start=\"2665\" data-end=\"2698\"\u003ePartial load (30%\/50%): 15.6 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2699\" data-end=\"2740\"\u003e  \u003cp data-start=\"2701\" data-end=\"2740\"\u003eEfficiency at rated power: 82.7%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2741\" data-end=\"2781\"\u003e  \u003cp data-start=\"2743\" data-end=\"2781\"\u003eEfficiency at 30%\/50%: 84.1%\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2783\" data-end=\"2855\"\u003eLambda technology supports clean and stable combustion.\u003c\/p\u003e  \u003chr data-start=\"2857\" data-end=\"2860\"\u003e  \u003ch2 data-start=\"2862\" data-end=\"2899\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"2901\" data-end=\"3002\"\u003eFor efficient and standards-compliant operation, the SLX 35 LAMBDA is typically combined with:\u003c\/p\u003e  \u003cul data-start=\"3004\" data-end=\"3137\"\u003e  \u003cli data-start=\"3004\" data-end=\"3022\"\u003e  \u003cp data-start=\"3006\" data-end=\"3022\"\u003eBuffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3023\" data-end=\"3062\"\u003e  \u003cp data-start=\"3025\" data-end=\"3062\"\u003eReturn flow booster\/mixing device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3063\" data-end=\"3094\"\u003e  \u003cp data-start=\"3065\" data-end=\"3094\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3095\" data-end=\"3116\"\u003e  \u003cp data-start=\"3097\" data-end=\"3116\"\u003eSafety valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3117\" data-end=\"3137\"\u003e  \u003cp data-start=\"3119\" data-end=\"3137\"\u003eExpansion vessel\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3139\" data-end=\"3250\"\u003eSuitable \u003cstrong data-start=\"3148\" data-end=\"3209\"\u003eBuffer storage tanks, return temperature boosts and safety groups\u003c\/strong\u003e You can find them in our product range at gemashop.de.\u003c\/p\u003e  \u003chr data-start=\"3252\" data-end=\"3255\"\u003e  \u003ch2 data-start=\"3257\" data-end=\"3276\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3278\" data-end=\"3731\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3278\" data-end=\"3296\"\u003e  \u003ctr data-start=\"3278\" data-end=\"3296\"\u003e  \u003cth data-start=\"3278\" data-end=\"3288\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3288\" data-end=\"3296\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3316\" data-end=\"3731\"\u003e  \u003ctr data-start=\"3316\" data-end=\"3346\"\u003e  \u003ctd data-start=\"3316\" data-end=\"3329\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"3329\" data-end=\"3346\" data-col-size=\"sm\"\u003eATTACK s.r.o.\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3347\" data-end=\"3373\"\u003e  \u003ctd data-start=\"3347\" data-end=\"3356\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3356\" data-end=\"3373\" data-col-size=\"sm\"\u003eSLX 35 LAMBDA\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3374\" data-end=\"3420\"\u003e  \u003ctd data-start=\"3374\" data-end=\"3387\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"3387\" data-end=\"3420\" data-col-size=\"sm\"\u003eWood gasification hot water boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3421\" data-end=\"3462\"\u003e  \u003ctd data-start=\"3421\" data-end=\"3434\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-start=\"3434\" data-end=\"3462\" data-col-size=\"sm\"\u003eFirewood ≤ 25% moisture content\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3463\" data-end=\"3494\"\u003e  \u003ctd data-start=\"3463\" data-end=\"3483\" data-col-size=\"sm\"\u003eNominal heat output\u003c\/td\u003e  \u003ctd data-start=\"3483\" data-end=\"3494\" data-col-size=\"sm\"\u003e35.2 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3495\" data-end=\"3525\"\u003e  \u003ctd data-start=\"3495\" data-end=\"3514\" data-col-size=\"sm\"\u003ePart load power\u003c\/td\u003e  \u003ctd data-start=\"3514\" data-end=\"3525\" data-col-size=\"sm\"\u003e15.6 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3526\" data-end=\"3564\"\u003e  \u003ctd data-start=\"3526\" data-end=\"3554\" data-col-size=\"sm\"\u003eEfficiency Rated Power\u003c\/td\u003e  \u003ctd data-start=\"3554\" data-end=\"3564\" data-col-size=\"sm\"\u003e82.7%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3565\" data-end=\"3599\"\u003e  \u003ctd data-start=\"3565\" data-end=\"3589\" data-col-size=\"sm\"\u003eEfficiency at partial load\u003c\/td\u003e  \u003ctd data-start=\"3589\" data-end=\"3599\" data-col-size=\"sm\"\u003e84.1%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3600\" data-end=\"3632\"\u003e  \u003ctd data-start=\"3600\" data-end=\"3621\" data-col-size=\"sm\"\u003eMaximum operating pressure.\u003c\/td\u003e  \u003ctd data-start=\"3621\" data-end=\"3632\" data-col-size=\"sm\"\u003e2.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3633\" data-end=\"3670\"\u003e  \u003ctd data-start=\"3633\" data-end=\"3660\" data-col-size=\"sm\"\u003eMinimum chimney diameter\u003c\/td\u003e  \u003ctd data-start=\"3660\" data-end=\"3670\" data-col-size=\"sm\"\u003e150 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3671\" data-end=\"3706\"\u003e  \u003ctd data-start=\"3671\" data-end=\"3694\" data-col-size=\"sm\"\u003eRecommended chimney draft\u003c\/td\u003e  \u003ctd data-start=\"3694\" data-end=\"3706\" data-col-size=\"sm\"\u003e23 Pa\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3707\" data-end=\"3731\"\u003e  \u003ctd data-start=\"3707\" data-end=\"3714\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-start=\"3714\" data-end=\"3731\" data-col-size=\"sm\"\u003eEN 303-5:2012\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3733\" data-end=\"3736\"\u003e  \u003ch2 data-start=\"3738\" data-end=\"3753\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3755\" data-end=\"3837\"\u003e  \u003cli data-start=\"3755\" data-end=\"3792\"\u003e  \u003cp data-start=\"3757\" data-end=\"3792\"\u003eATTACK SLX 35 LAMBDA wood gasifier\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3793\" data-end=\"3816\"\u003e  \u003cp data-start=\"3795\" data-end=\"3816\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3817\" data-end=\"3837\"\u003e  \u003cp data-start=\"3819\" data-end=\"3837\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"3839\" data-end=\"3842\"\u003e  \u003ch2 data-start=\"3844\" data-end=\"3877\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"3879\" data-end=\"3981\"\u003eInstallation and commissioning must only be carried out by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"3983\" data-end=\"4001\"\u003eImportant instructions:\u003c\/p\u003e  \u003cul data-start=\"4003\" data-end=\"4234\"\u003e  \u003cli data-start=\"4003\" data-end=\"4055\"\u003e  \u003cp data-start=\"4005\" data-end=\"4055\"\u003eThermal safety device absolutely necessary\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4056\" data-end=\"4122\"\u003e  \u003cp data-start=\"4058\" data-end=\"4122\"\u003eReturn temperature boost necessary to prevent condensation\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4123\" data-end=\"4160\"\u003e  \u003cp data-start=\"4125\" data-end=\"4160\"\u003eCompliance with chimney requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4161\" data-end=\"4234\"\u003e  \u003cp data-start=\"4163\" data-end=\"4234\"\u003eRegular cleaning of ash box, turbulators and heat exchangers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4236\" data-end=\"4304\"\u003eThe warranty may be limited if the installation is improper.\u003c\/p\u003e  \u003chr data-start=\"4306\" data-end=\"4309\"\u003e  \u003ch2 data-start=\"4311\" data-end=\"4317\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4319\" data-end=\"4439\"\u003e\u003cstrong data-start=\"4319\" data-end=\"4358\"\u003e1. What does the lambda control do?\u003c\/strong\u003e\u003cbr data-start=\"4358\" data-end=\"4361\"\u003eIt measures the oxygen content in the exhaust gas and automatically regulates the air supply.\u003c\/p\u003e  \u003cp data-start=\"4441\" data-end=\"4527\"\u003e\u003cstrong data-start=\"4441\" data-end=\"4486\"\u003e2. What is the power output of the SLX 35 LAMBDA?\u003c\/strong\u003e\u003cbr data-start=\"4486\" data-end=\"4489\"\u003eThe nominal heat output is 35.2 kW.\u003c\/p\u003e  \u003cp data-start=\"4529\" data-end=\"4612\"\u003e\u003cstrong data-start=\"4529\" data-end=\"4568\"\u003e3. Which fuel is permitted?\u003c\/strong\u003e\u003cbr data-start=\"4568\" data-end=\"4571\"\u003eFirewood with a maximum moisture content of 25%.\u003c\/p\u003e  \u003cp data-start=\"4614\" data-end=\"4739\"\u003e\u003cstrong data-start=\"4614\" data-end=\"4654\"\u003e4. Is a buffer storage tank necessary?\u003c\/strong\u003e\u003cbr data-start=\"4654\" data-end=\"4657\"\u003eA buffer storage tank is recommended for efficient and compliant operation.\u003c\/p\u003e  \u003cp data-start=\"4741\" data-end=\"4799\"\u003e\u003cstrong data-start=\"4741\" data-end=\"4788\"\u003e5. What is the maximum operating pressure?\u003c\/strong\u003e\u003cbr data-start=\"4788\" data-end=\"4791\"\u003e2.5 bar.\u003c\/p\u003e  \u003cp data-start=\"4801\" data-end=\"4913\"\u003e\u003cstrong data-start=\"4801\" data-end=\"4838\"\u003e6. How often does it need to be cleaned?\u003c\/strong\u003e\u003cbr data-start=\"4838\" data-end=\"4841\"\u003eEmpty the ash box daily, and clean the heat exchanger regularly according to the operating instructions.\u003c\/p\u003e  \u003chr data-start=\"4915\" data-end=\"4918\"\u003e  \u003ch2 data-start=\"4920\" data-end=\"4928\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"4930\" data-end=\"5210\"\u003eThe \u003cstrong data-start=\"4934\" data-end=\"4964\"\u003eATTACK SLX 35 LAMBDA 35 kW\u003c\/strong\u003e Combines high-performance wood gasification technology with modern lambda control. An efficient and convenient solution for sustainable heating with logs in large residential buildings. Order now and benefit from precise combustion control.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49418750624092,"sku":"ASLXL35","price":5665.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXlambda-webrender.webp?v=1774512431","url":"https:\/\/si.gemashop.de\/products\/attack-slx-35-lambda-wood-carburettor-35-kw","provider":"GEMA Shop","version":"1.0","type":"link"}