{"product_id":"ventil-bnt-montageanleitung-physikalische-daten-r2d2-aqmos-technische","title":"Water softening system R2D2","description":"\u003ch2\u003eR2D2 water softening system with 1\" Connection set – Innovative and efficient water purifier\u003c\/h2\u003e  \u003ch3\u003eStructure and design of the plant\u003c\/h3\u003e  \u003cp\u003eThe R2D2 water softener impresses with its robust cabinet housing, which not only protects the internal components but also serves as a salt reservoir. A removable lid makes maintenance and refilling particularly easy.\u003c\/p\u003e  \u003cp\u003eInside the cabinet is a pressure-resistant, integrated GRP pressure vessel filled with high-quality ion exchange resin. This resin forms the heart of the system and ensures permanently soft water through the effective exchange of hardness-causing minerals.\u003c\/p\u003e  \u003ch3\u003eQuantity control with the BNT 1650 valve\u003c\/h3\u003e  \u003cp\u003eThe integrated BNT 1650 valve enables precise, water-volume-controlled regeneration of the system. The built-in water meter measures the softened water consumption and automatically initiates the regeneration process as soon as the preset flow rate is reached.\u003c\/p\u003e  \u003cp\u003eThe regeneration process starts daily at 2:00 AM, with the valve preset to \u0026quot;Delayed volume-controlled regeneration\u0026quot;. This ensures that the water softener operates continuously at optimal levels and reliably monitors consumption.\u003c\/p\u003e  \u003ch3\u003eHigh-quality ion exchange resin\u003c\/h3\u003e  \u003cp\u003eThe high-performance ion exchange resin is saturated with sodium ions and plays a central role in the water softening process. As tap water passes through, calcium and magnesium ions are effectively exchanged for sodium ions, resulting in soft water.\u003c\/p\u003e  \u003cp\u003eThe long-lasting resin, when regularly regenerated, ensures consistently high water quality and boasts a lifespan of over 20 years. This guarantees sustainable and economical water treatment.\u003c\/p\u003e  \u003ch3\u003eAutomatic regeneration of the water softening system\u003c\/h3\u003e  \u003cp\u003eOnce the resin is fully saturated with calcium and magnesium ions, the self-regeneration process begins. A highly concentrated saline solution is automatically passed over the resin, reversing the exchange processes and re-enriching the material with sodium ions.\u003c\/p\u003e  \u003cp\u003eDuring this process, the calcium and magnesium ions, along with excess salt solution, are discharged into the wastewater via a separate drain. This allows the resin to be regenerated quickly and made available for further applications.\u003c\/p\u003e  \u003ch3\u003eForced regeneration and safety features\u003c\/h3\u003e  \u003cp\u003eTo prevent bacterial growth in the resin bed, the timed forced regeneration ensures that the system automatically switches to regeneration mode on the 10th day after a prolonged period of inactivity. This function guarantees continuous hygienic water treatment.\u003c\/p\u003e  \u003cp\u003eAn integrated safety float valve with a buoy protects the cabinet housing from overflowing water, ensuring reliable operation even in unusual situations. Depending on water hardness and consumption, the system's salt reservoir lasts for approximately 3 to 4 months.\u003c\/p\u003e  \u003ch3\u003eTechnical data and performance characteristics\u003c\/h3\u003e  \u003cp\u003eThe \u003cstrong\u003eWater softening system\u003c\/strong\u003e R2D2 is available in various models designed for households of 4 to 7 people. The system's capacity varies depending on water hardness, with some models capable of softening up to 7,200 liters.\u003c\/p\u003e  \u003cp\u003eThe various technical parameters include a nominal flow rate based on DIN 16939 and a regeneration time of between 30 and 45 minutes. Furthermore, the system is designed for a maximum pipe water flow pressure of 6 bar and remains reliably operational at a minimum pressure of 2 bar.\u003c\/p\u003e  \u003cp\u003eWith a large salt capacity of up to 50 kg and robust GRP pressure bottles in various sizes, the system offers a flexible solution for diverse needs. Its low power consumption of just 3 watts further underscores the energy efficiency of this innovative product.\u003c\/p\u003e  \u003ch3\u003eTechnical data\u003c\/h3\u003e  \u003cstyle type=\"text\/css\"\u003e \ttable.tableizer-table { \t\tfont-size: 12px; \t\tborder: 1px solid #CCC;  \t\tfont-family: Arial, Helvetica, sans-serif; \t}  \t.tableizer-table td { \t\tpadding: 4px; \t\tmargin: 3px; \t\tborder: 1px solid #CCC; \t} \t.tableizer-table th { \t\tbackground-color: #104E8B;  \t\tcolor: #FFF; \t\tfont-weight: bold; \t} \u003c\/style\u003e  \u003ctable class=\"tableizer-table\"\u003e  \u003cthead\u003e  \u003ctr class=\"tableizer-firstrow\"\u003e  \u003cth\u003eTechnical data\u003c\/th\u003e  \u003cth\u003eBM-R2D2-32\u003c\/th\u003e  \u003cth\u003eBM-R2D2-48\u003c\/th\u003e  \u003cth\u003eBM-R2D2-72\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody\u003e  \u003ctr\u003e  \u003ctd\u003ePerformance data\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003efor households up to\u003c\/td\u003e  \u003ctd\u003e4 people\u003c\/td\u003e  \u003ctd\u003e5 people\u003c\/td\u003e  \u003ctd\u003e7 people\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCapacity at 10°dH\u003c\/td\u003e  \u003ctd\u003e3,200 L\u003c\/td\u003e  \u003ctd\u003e4,800 L\u003c\/td\u003e  \u003ctd\u003e7,200 L\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCapacity at 15°dH\u003c\/td\u003e  \u003ctd\u003e2,130 L\u003c\/td\u003e  \u003ctd\u003e3,200 L\u003c\/td\u003e  \u003ctd\u003e4,800 L\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCapacity at 20°dH\u003c\/td\u003e  \u003ctd\u003e1,600 L\u003c\/td\u003e  \u003ctd\u003e2,400 L\u003c\/td\u003e  \u003ctd\u003e3,600 L\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eNominal flow rate DIN16939 (20°dH to 8°dH)\u003c\/td\u003e  \u003ctd\u003e1.0 m³\/h\u003c\/td\u003e  \u003ctd\u003e1.7 m³\/h\u003c\/td\u003e  \u003ctd\u003e2.1 m³\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eNominal flow rate from 20°C to 0.5°dH (40 BV\/h)\u003c\/td\u003e  \u003ctd\u003e0.24 m³\/h\u003c\/td\u003e  \u003ctd\u003e0.5 m³\/h\u003c\/td\u003e  \u003ctd\u003e0.7 m³\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003emax. pipe water flow pressure\u003c\/td\u003e  \u003ctd\u003e6.0 bar\u003c\/td\u003e  \u003ctd\u003e6.0 bar\u003c\/td\u003e  \u003ctd\u003e6.0 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eminimum pipe water flow pressure\u003c\/td\u003e  \u003ctd\u003e2.0 bar\u003c\/td\u003e  \u003ctd\u003e2.0 bar\u003c\/td\u003e  \u003ctd\u003e2.0 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ePressure loss at maximum flow rate\u003c\/td\u003e  \u003ctd\u003e0.6 bar\u003c\/td\u003e  \u003ctd\u003e0.6 bar\u003c\/td\u003e  \u003ctd\u003e0.6 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eSalt consumption per regeneration\u003c\/td\u003e  \u003ctd\u003e1.28 kg\u003c\/td\u003e  \u003ctd\u003e1.92 kg\u003c\/td\u003e  \u003ctd\u003e2.88 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eRegeneration time\u003c\/td\u003e  \u003ctd\u003e30 minutes\u003c\/td\u003e  \u003ctd\u003e40 minutes\u003c\/td\u003e  \u003ctd\u003e45 minutes\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ePhysical data Cabinet housing\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCabinet height\u003c\/td\u003e  \u003ctd\u003e650 mm\u003c\/td\u003e  \u003ctd\u003e825 mm\u003c\/td\u003e  \u003ctd\u003e1,100 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eWide cabinet enclosures\u003c\/td\u003e  \u003ctd\u003e220 mm\u003c\/td\u003e  \u003ctd\u003e220 mm\u003c\/td\u003e  \u003ctd\u003e220 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eDeep cabinet cases\u003c\/td\u003e  \u003ctd\u003e460 mm\u003c\/td\u003e  \u003ctd\u003e460 mm\u003c\/td\u003e  \u003ctd\u003e460 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMaximum salt supply\u003c\/td\u003e  \u003ctd\u003e25 kg\u003c\/td\u003e  \u003ctd\u003e40 kg\u003c\/td\u003e  \u003ctd\u003e50 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ePhysical data of GRP pressure vessel\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eGRP pressure bottle type\u003c\/td\u003e  \u003ctd\u003e8\"x17\"\u003c\/td\u003e  \u003ctd\u003e8\"x24\"\u003c\/td\u003e  \u003ctd\u003e8\"x35\"\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eresin content\u003c\/td\u003e  \u003ctd\u003e8 L\u003c\/td\u003e  \u003ctd\u003e12 L\u003c\/td\u003e  \u003ctd\u003e18 L\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eControl valve\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003esteering head\u003c\/td\u003e  \u003ctd\u003eBNT 1650\u003c\/td\u003e  \u003ctd\u003eBNT 1650\u003c\/td\u003e  \u003ctd\u003eBNT 1650\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eWater connections\u003c\/td\u003e  \u003ctd\u003e1\" AG\u003c\/td\u003e  \u003ctd\u003e1\" AG\u003c\/td\u003e  \u003ctd\u003e1\" AG\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eWastewater connection\u003c\/td\u003e  \u003ctd\u003e12 mm\u003c\/td\u003e  \u003ctd\u003e12 mm\u003c\/td\u003e  \u003ctd\u003e12 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectrical properties\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eelectricity consumption\u003c\/td\u003e  \u003ctd\u003e3 watts\u003c\/td\u003e  \u003ctd\u003e3 watts\u003c\/td\u003e  \u003ctd\u003e3 watts\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectrical connection\u003c\/td\u003e  \u003ctd\u003e230\/50\/24 V\u003c\/td\u003e  \u003ctd\u003e230\/50\/24 V\u003c\/td\u003e  \u003ctd\u003e230\/50\/24 V\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003emax.Water temperature\u003c\/td\u003e  \u003ctd\u003e30 °C\u003c\/td\u003e  \u003ctd\u003e30 °C\u003c\/td\u003e  \u003ctd\u003e30 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eWeight of the plant\u003c\/td\u003e  \u003ctd\u003e17 kg\u003c\/td\u003e  \u003ctd\u003e27 kg\u003c\/td\u003e  \u003ctd\u003e32 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003cp\u003e  \u003c\/p\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003eWater softening system R2D2\u003c\/li\u003e  \u003cli\u003eMounting material\u003c\/li\u003e  \u003cli\u003eAssembly instructions\u003c\/li\u003e  \u003cli\u003eUser manual\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eDownload\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Montage.pdf?v=1741686853\" target=\"_blank\" rel=\"noopener\" title=\"Montageanleitung\" aria-label=\"Besuchen Sie eine Webseite über Montageanleitung\"\u003eAssembly instructions\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Bedienung.pdf?v=1741686890\" target=\"_blank\" rel=\"noopener\" title=\"Bedienungsanleitung\" aria-label=\"Besuchen Sie eine Webseite über Bedienungsanleitung\"\u003eUser manual\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Datenblatte_R2D2_32.pdf?v=1741686822\" target=\"_blank\" rel=\"noopener\" title=\"Datenblatt r2d2-32\" aria-label=\"Besuchen Sie eine Webseite über Datenblatt r2d2-32\"\u003eR2D2-32 Datasheet\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Datenblatt_R2D2_48.pdf?v=1741686892\" rel=\"noopener\" target=\"_blank\" title=\"Datenblatt r2d2-48\" aria-label=\"Besuchen Sie eine Webseite über Datenblatt r2d2-48\"\u003eR2D2-48 Datasheet\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Datenblatt_R2D2_72.pdf?v=1741686823\" target=\"_blank\" rel=\"noopener\" title=\"Datenblatt r2d2-72\" aria-label=\"Besuchen Sie eine Webseite über Datenblatt r2d2-72\"\u003eR2D2-72 Datasheet\u003c\/a\u003e\u003c\/li\u003e  \u003c\/ul\u003e","brand":"Aqmos","offers":[{"title":"1-4 people","offer_id":47721493889372,"sku":"R2D2-32","price":421.96,"currency_code":"EUR","in_stock":true},{"title":"2-5 people","offer_id":47721493922140,"sku":"R2D2-48","price":484.69,"currency_code":"EUR","in_stock":true},{"title":"2-7 people","offer_id":47721493954908,"sku":"R2D2-72","price":526.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/wasserenthartungsanlage-r2d2-8587215.jpg?v=1770692959","url":"https:\/\/si.gemashop.de\/hr\/products\/valve-bnt-assembly-instructions-physical-data-r2d2-aqmos-technical-1","provider":"GEMA Shop","version":"1.0","type":"link"}