{"product_id":"brennwert-gastherme-vaillant-ecotec-exclusive-pumpe-0063cu3910-ii2n3p","title":"Vaillant ecoTEC exclusive condensing gas boiler with modern technology","description":"\u003cdiv class=\"base__image-text-section overflow-auto\"\u003e  \u003cdiv class=\"base__image-text-section__container\"\u003e  \u003ch2\u003eVaillant coTEC exclusive VC\/VCW 1-7 condensing gas boiler\u003c\/h2\u003e  \u003cp\u003e\u003cstrong\u003eA strong argument: Vaillant condensing gas boiler Green iQ\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe ecoTEC exclusive meets the highest requirements for sustainable technologies and intelligent networking – and has been awarded the [award name missing].\u003cspan\u003e  \u003c\/span\u003eVaillant Green iQ Label\u003cspan\u003e  \u003c\/span\u003eexcellent.\u003c\/p\u003e  \u003cp\u003eThe gas condensing boiler is produced in a resource-saving manner and consists of approximately 85% high-quality recyclable materials.\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cdiv data-content-toggle-deactivate-at-breakpoint=\"640\" data-content-toggle-theme-activated-only=\"default\" class=\"content-toggle-group content-toggle-group--theme-expand content-toggle--is-deactivated\"\u003e  \u003cdiv class=\"content-toggle\"\u003e  \u003ch3 aria-controls=\"benefitContent2321\" id=\"benefitTrigger2321\" role=\"tab\" aria-expanded=\"true\" aria-selected=\"true\" class=\"content-toggle__trigger\" tabindex=\"0\"\u003eGEG-compliant: H2 Ready and Bio-natural gas\u003c\/h3\u003e  \u003cdiv aria-labelledby=\"benefitTrigger2321\" id=\"benefitContent2321\" role=\"tabpanel\" aria-hidden=\"false\" class=\"content-toggle__content\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cp\u003eWith the ecoTEC exclusive, we are already taking a big step towards the future:\u003c\/p\u003e  \u003cp\u003eThe device is already suitable for operation with up to 20% hydrogen* and up to 100% biogas. No manual adjustments are required. Furthermore, it\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eH2 Ready\u003c\/b\u003e\u003cspan\u003e  \u003c\/span\u003ein accordance with the GEG, because the ecoTEC exclusive VC can be converted to run on 100% hydrogen* using a conversion kit.\u003c\/p\u003e  \u003cp\u003eThis will be available from 2026. You can find more information about hydrogen here.\u003cspan\u003e  \u003c\/span\u003ehere.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eThe self-adapting combustion system IoniDetect also offers many advantages:\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e  \u003cli\u003eIt continuously monitors combustion quality via the ionization current and optimizes it in case of deviations.\u003c\/li\u003e  \u003cli\u003eIt recognizes all types of natural gas and compensates for fluctuations in gas quality.\u003c\/li\u003e  \u003cli\u003eOptimal combustion guaranteed\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eOur ecoTEC exclusive is ideally suited for combination with heat pumps to create sustainable hybrid systems.\u003c\/p\u003e  \u003cp\u003eBy utilizing ambient heat, a significant proportion of the required energy is generated sustainably.\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cdiv class=\"content-toggle\"\u003e  \u003ch3 aria-controls=\"benefitContent2324\" id=\"benefitTrigger2324\" role=\"tab\" aria-expanded=\"true\" aria-selected=\"true\" class=\"content-toggle__trigger\" tabindex=\"0\"\u003eIncludes internet module for app control\u003c\/h3\u003e  \u003cdiv aria-labelledby=\"benefitTrigger2324\" id=\"benefitContent2324\" role=\"tabpanel\" aria-hidden=\"false\" class=\"content-toggle__content\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cp\u003eThe internet module\u003cspan\u003e  \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"SensoNet-VR921\" href=\"\/hr\/products\/vaillant-heizungsregler-sensocomfort-vrc-integrierte-ansteuerung\" target=\"_blank\" aria-label=\"SensoNet-VR921\"\u003esensoNET\u003c\/a\u003e\u003cspan\u003e  \u003c\/span\u003eThe ecoTEC exclusive can be ordered free of charge using the voucher on the front of the device. (In conjunction with the appropriate controller.)\u003cspan\u003e  \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"senso-direct\" href=\"\/hr\/products\/witterungsgefuehrter-einkreisregler-vaillant-ecotec-plus-exclusive?_pos=3\u0026amp;_psq=senso\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" aria-label=\"senso-direct\"\u003esensoDIRECT\u003c\/a\u003e\u003cspan\u003e  \u003c\/span\u003eor\u003cspan\u003e  \u003c\/span\u003e\u003ca href=\"\/hr\/products\/vaillant-heizungsregler-sensocomfort-vrc-integrierte-ansteuerung?_pos=3\u0026amp;_psq=sens\u0026amp;_ss=e\u0026amp;_v=1.0\" title=\"comfort-720\" rel=\"noopener\" target=\"_blank\" aria-label=\"comfort-720\"\u003esensoCOMFORT\u003c\/a\u003e\u003cspan\u003e  \u003c\/span\u003eIt enables your customers to conveniently control the system via an app – and allows you to manage your systems remotely, saving you time.\u003cspan\u003e  \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.myvaillantpro.de\/service\/digitale-anlagenbetreuung\/myvaillant-pro\" target=\"_blank\" title=\"Myvaillant pro\" aria-label=\"Besuchen Sie eine Webseite über Myvaillant pro\"\u003emyVAILLANT Pro\u003c\/a\u003e.\u003c\/p\u003e  \u003cp\u003eSo\u003cspan\u003e  \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.youtube.com\/watch?v=6MNKNsDOVVE\u0026amp;feature=youtu.be\" target=\"_blank\" title=\"Erhalten und installieren\" aria-label=\"Besuchen Sie eine Webseite über Erhalten und installieren\"\u003eobtain and install\u003c\/a\u003e\u003cspan\u003e  \u003c\/span\u003eYour customers the internet module:\u003c\/p\u003e  \u003cp\u003e1. Order via the QR code on the front of the device\u003c\/p\u003e  \u003cp\u003e2. Easy connection under the ecoTEC exclusive via plug-and-play\u003c\/p\u003e  \u003cp\u003e3.\u003cspan\u003e  \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.myvaillantpro.de\/produkte\/mobile-apps\/myvaillant-app\" target=\"_blank\" title=\"Myvaillant app\" aria-label=\"Besuchen Sie eine Webseite über Myvaillant app\"\u003emyVAILLANT App\u003c\/a\u003e\u003cspan\u003e  \u003c\/span\u003eDownload and get started\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cdiv class=\"content-toggle\"\u003e  \u003ch3 aria-controls=\"benefitContent2323\" id=\"benefitTrigger2323\" role=\"tab\" aria-expanded=\"true\" aria-selected=\"true\" class=\"content-toggle__trigger\" tabindex=\"0\"\u003eFast hydraulic balancing via app\u003c\/h3\u003e  \u003cdiv aria-labelledby=\"benefitTrigger2323\" id=\"benefitContent2323\" role=\"tabpanel\" aria-hidden=\"false\" class=\"content-toggle__content\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cp\u003eWith the integrated, communication-enabled, high-efficiency pump, you can perform hydraulic balancing significantly faster and more accurately. The app “\u003ca href=\"https:\/\/www.youtube.com\/watch?v=1qFy6N3adXA\u0026amp;feature=youtu.be\" rel=\"noopener noreferrer\" class=\"link--external\" target=\"_blank\" title=\"Grundfos go balance\" aria-label=\"Besuchen Sie eine Webseite über Grundfos go balance\"\u003eGrundfos GO Balance\u003c\/a\u003eThe app guides you step-by-step through the entire process and automatically calculates the recommended flow rate for each radiator. After the hydraulic balancing, you receive PDF documentation in the app. You can provide this to your customers as proof of professional implementation – particularly helpful for grant applications.\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cdiv class=\"content-toggle\"\u003e  \u003ch3 aria-controls=\"benefitContent2325\" id=\"benefitTrigger2325\" role=\"tab\" aria-expanded=\"true\" aria-selected=\"true\" class=\"content-toggle__trigger\" tabindex=\"0\"\u003ePerfect hot water preparation in the smallest space with the Vaillant condensing gas boiler VC\/VCW 1-7\u003c\/h3\u003e  \u003cdiv aria-labelledby=\"benefitTrigger2325\" id=\"benefitContent2325\" role=\"tabpanel\" aria-hidden=\"false\" class=\"content-toggle__content\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cp\u003eAs a combination unit with integrated hot water preparation (VCW), the ecoTEC exclusive, with its further developed heat exchanger concept, achieves an 8% higher efficiency than comparable standard units. It requires only 0.32 m² of wall space.The secondary heat exchanger, with its 35 plates, ensures a particularly high level of hot water comfort.\u003c\/p\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003cdiv class=\"content-toggle\"\u003e  \u003ch3 aria-controls=\"benefitContent2326\" id=\"benefitTrigger2326\" role=\"tab\" aria-expanded=\"true\" aria-selected=\"true\" class=\"content-toggle__trigger\" tabindex=\"0\"\u003eImportant technical information for Vaillant VC\/VCW 1-7 condensing gas boiler\u003c\/h3\u003e  \u003cdiv aria-labelledby=\"benefitTrigger2326\" id=\"benefitContent2326\" role=\"tabpanel\" aria-hidden=\"false\" class=\"content-toggle__content\"\u003e  \u003cdiv class=\"content-toggle__content__inner\"\u003e  \u003cul\u003e  \u003cli\u003eModulation: 1:10\u003c\/li\u003e  \u003cli\u003ePower ratings VC: 15, 20, 25, 30 kW\u003c\/li\u003e  \u003cli\u003ePower output VCW: 25 kW (even 36 kW in hot water mode)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003ch3\u003eTechnical data: Vaillant condensing gas boiler VC\/VCW 1-7\u003c\/h3\u003e  \u003cstyle type=\"text\/css\"\u003e \ttable.tableizer-table { \t\tfont-size: 12px; \t\tborder: 1px solid #CCC;  \t\tfont-family: Arial, Helvetica, sans-serif; \t}  \t.tableizer-table td { \t\tpadding: 4px; \t\tmargin: 3px; \t\tborder: 1px solid #CCC; \t} \t.tableizer-table th { \t\tbackground-color: #104E8B;  \t\tcolor: #FFF; \t\tfont-weight: bold; \t} \u003c\/style\u003e  \u003ctable class=\"tableizer-table\"\u003e  \u003cthead\u003e  \u003ctr class=\"tableizer-firstrow\"\u003e  \u003cth\u003eecoTEC exclusive\u003c\/th\u003e  \u003cth\u003eVC 15 CS\/1-7\u003c\/th\u003e  \u003cth\u003eVC 20 CS\/1-7\u003c\/th\u003e  \u003cth\u003eVC 25 CS\/1-7\u003c\/th\u003e  \u003cth\u003eVC 30 CS\/1-7\u003c\/th\u003e  \u003cth\u003eVCW 25\/36 CF \/1-7\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody\u003e  \u003ctr\u003e  \u003ctd\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating (A+++ - D)\u003c\/td\u003e  \u003ctd\u003eA\u003c\/td\u003e  \u003ctd\u003eA\u003c\/td\u003e  \u003ctd\u003eA\u003c\/td\u003e  \u003ctd\u003eA\u003c\/td\u003e  \u003ctd\u003eA\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHot water (A+ - F)\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003eA\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eTechnical data\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output at 50\/30 °C natural gas E, natural gas LL (Min - Max)\u003c\/td\u003e  \u003ctd\u003e2.8 - 16.4 kW\u003c\/td\u003e  \u003ctd\u003e2.8 - 21.6 kW\u003c\/td\u003e  \u003ctd\u003e2.8 - 27.0 kW\u003c\/td\u003e  \u003ctd\u003e3.8 - 32.5 kW\u003c\/td\u003e  \u003ctd\u003e3.4 - 27.1 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output at 50\/30 °C liquid gas\u003c\/td\u003e  \u003ctd\u003e5.4 - 16.4 kW\u003c\/td\u003e  \u003ctd\u003e5.4 - 21.0 kW\u003c\/td\u003e  \u003ctd\u003e5.4 - 26.4 kW\u003c\/td\u003e  \u003ctd\u003e8.4 - 32.5 kW\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003e(Min - Max)\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output at 80\/60 °C natural gas E, natural gas LL (Min - Max)\u003c\/td\u003e  \u003ctd\u003e2.5 - 14.8 kW\u003c\/td\u003e  \u003ctd\u003e2.5 - 19.7 kW\u003c\/td\u003e  \u003ctd\u003e2.5 - 24.7 kW\u003c\/td\u003e  \u003ctd\u003e3.5 - 30.0 kW\u003c\/td\u003e  \u003ctd\u003e3.0 - 25.0 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output at 80\/60 °C liquid gas\u003c\/td\u003e  \u003ctd\u003e4.8 - 14.8 kW\u003c\/td\u003e  \u003ctd\u003e4.8 - 19.7 kW\u003c\/td\u003e  \u003ctd\u003e4.8 - 24.7 kW\u003c\/td\u003e  \u003ctd\u003e7.8 - 30.0 kW\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003e(Min - Max)\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating output during hot water operation\u003c\/td\u003e  \u003ctd\u003e20 kW\u003c\/td\u003e  \u003ctd\u003e24 kW\u003c\/td\u003e  \u003ctd\u003e27.5 kW\u003c\/td\u003e  \u003ctd\u003e34.8 kW\u003c\/td\u003e  \u003ctd\u003e36.4 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eNatural gas E, Natural gas LL, Liquefied petroleum gas (Max)\u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003ctd\u003e  \u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eContinuous hot water supply\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003ctd\u003e17.6 l\/min\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eEfficiency at 30% according to EN 15502 Natural gas E, Natural gas LL, Liquefied petroleum gas\u003c\/td\u003e  \u003ctd\u003e109%\u003c\/td\u003e  \u003ctd\u003e110%\u003c\/td\u003e  \u003ctd\u003e109%\u003c\/td\u003e  \u003ctd\u003e110%\u003c\/td\u003e  \u003ctd\u003e110%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeat load for natural gas E, natural gas LL (Min - Max)\u003c\/td\u003e  \u003ctd\u003e2.7 - 15.3 kW\u003c\/td\u003e  \u003ctd\u003e2.7 - 20.4 kW\u003c\/td\u003e  \u003ctd\u003e2.7 - 25.5 kW\u003c\/td\u003e  \u003ctd\u003e3.7 - 30.6 kW\u003c\/td\u003e  \u003ctd\u003e3.2 - 25.5 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eSeasonal space heating efficiency ηs\u003c\/td\u003e  \u003ctd\u003e93%\u003c\/td\u003e  \u003ctd\u003e94%\u003c\/td\u003e  \u003ctd\u003e94%\u003c\/td\u003e  \u003ctd\u003e94%\u003c\/td\u003e  \u003ctd\u003e94%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eAddition of hydrogen\u003c\/td\u003e  \u003ctd\u003e20%\u003c\/td\u003e  \u003ctd\u003e20%\u003c\/td\u003e  \u003ctd\u003e20%\u003c\/td\u003e  \u003ctd\u003e20%\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eBiogas\u003c\/td\u003e  \u003ctd\u003eup to 100%\u003c\/td\u003e  \u003ctd\u003eup to 100%\u003c\/td\u003e  \u003ctd\u003eup to 100%\u003c\/td\u003e  \u003ctd\u003eup to 100%\u003c\/td\u003e  \u003ctd\u003eup to 100%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectricPower consumption at 30%\u003c\/td\u003e  \u003ctd\u003e28 W\u003c\/td\u003e  \u003ctd\u003e47 W\u003c\/td\u003e  \u003ctd\u003e54 W\u003c\/td\u003e  \u003ctd\u003e58 W\u003c\/td\u003e  \u003ctd\u003e49 W\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectrical power consumption (max)\u003c\/td\u003e  \u003ctd\u003e81 W\u003c\/td\u003e  \u003ctd\u003e59 W\u003c\/td\u003e  \u003ctd\u003e91 W\u003c\/td\u003e  \u003ctd\u003e80 W\u003c\/td\u003e  \u003ctd\u003e61 W\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eElectrical power consumption in standby mode\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003ctd\u003e2 W\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eIncluded components in electrical power\u003c\/td\u003e  \u003ctd\u003epump\u003c\/td\u003e  \u003ctd\u003epump\u003c\/td\u003e  \u003ctd\u003epump\u003c\/td\u003e  \u003ctd\u003epump\u003c\/td\u003e  \u003ctd\u003epump\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eContents on the heating side\u003c\/td\u003e  \u003ctd\u003e2.1 l\u003c\/td\u003e  \u003ctd\u003e2.1 l\u003c\/td\u003e  \u003ctd\u003e2.1 l\u003c\/td\u003e  \u003ctd\u003e2.6 l\u003c\/td\u003e  \u003ctd\u003e2.6 l\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eMaximum operating pressure on the heating side\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003ctd\u003e3 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating temperature, flow temperature (max)\u003c\/td\u003e  \u003ctd\u003e85 °C\u003c\/td\u003e  \u003ctd\u003e85 °C\u003c\/td\u003e  \u003ctd\u003e85 °C\u003c\/td\u003e  \u003ctd\u003e85 °C\u003c\/td\u003e  \u003ctd\u003e85 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eConnection value for natural gas E\u003c\/td\u003e  \u003ctd\u003e2.2 m³\/h\u003c\/td\u003e  \u003ctd\u003e2.6 m³\/h\u003c\/td\u003e  \u003ctd\u003e3.0 m³\/h\u003c\/td\u003e  \u003ctd\u003e3.8 m³\/h\u003c\/td\u003e  \u003ctd\u003e3.6 m³\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eConnection value for natural gas LL\u003c\/td\u003e  \u003ctd\u003e2.5 m³\/h\u003c\/td\u003e  \u003ctd\u003e3.0 m³\/h\u003c\/td\u003e  \u003ctd\u003e3.5 m³\/h\u003c\/td\u003e  \u003ctd\u003e4.4 m³\/h\u003c\/td\u003e  \u003ctd\u003e4.2 m³\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eConnection value for liquefied petroleum gas\u003c\/td\u003e  \u003ctd\u003e0.8 kg\/h\u003c\/td\u003e  \u003ctd\u003e1.0 kg\/h\u003c\/td\u003e  \u003ctd\u003e1.1 kg\/h\u003c\/td\u003e  \u003ctd\u003e1.3 kg\/h\u003c\/td\u003e  \u003ctd\u003e-\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCondensation quantity at 50\/30 °C\u003c\/td\u003e  \u003ctd\u003e1.53 l\/h\u003c\/td\u003e  \u003ctd\u003e2.04 l\/h\u003c\/td\u003e  \u003ctd\u003e2.55 l\/h\u003c\/td\u003e  \u003ctd\u003e3.06 l\/h\u003c\/td\u003e  \u003ctd\u003e2.55 l\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ePump flow rate at ΔT 20K (residual delivery head)\u003c\/td\u003e  \u003ctd\u003e645 (200) l\/h (mbar)\u003c\/td\u003e  \u003ctd\u003e860 (200) l\/h (mbar)\u003c\/td\u003e  \u003ctd\u003e1.075 (200) l\/h (mbar)\u003c\/td\u003e  \u003ctd\u003e1,290 (200) l\/h (mbar)\u003c\/td\u003e  \u003ctd\u003e1.0.75 (250) l\/h (mbar)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eExpansion vessel contents\u003c\/td\u003e  \u003ctd\u003e10 l\u003c\/td\u003e  \u003ctd\u003e10 l\u003c\/td\u003e  \u003ctd\u003e10 l\u003c\/td\u003e  \u003ctd\u003e10 l\u003c\/td\u003e  \u003ctd\u003e10 l\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eTension\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e  \u003ctd\u003e230 V\/50 Hz\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eProduct dimensions (height\/width\/depth)\u003c\/td\u003e  \u003ctd\u003e720\/440\/348 mm\u003c\/td\u003e  \u003ctd\u003e720\/440\/348 mm\u003c\/td\u003e  \u003ctd\u003e720\/440\/348 mm\u003c\/td\u003e  \u003ctd\u003e720\/440\/348 mm\u003c\/td\u003e  \u003ctd\u003e720\/440\/382 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eProduct weight\u003c\/td\u003e  \u003ctd\u003e34 kg\u003c\/td\u003e  \u003ctd\u003e34 kg\u003c\/td\u003e  \u003ctd\u003e34 kg\u003c\/td\u003e  \u003ctd\u003e39 kg\u003c\/td\u003e  \u003ctd\u003e43 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eHeating connection (flow and return)\u003c\/td\u003e  \u003ctd\u003eG 3\/4\u003c\/td\u003e  \u003ctd\u003eG 3\/4\u003c\/td\u003e  \u003ctd\u003eG 3\/4\u003c\/td\u003e  \u003ctd\u003eG 3\/4\u003c\/td\u003e  \u003ctd\u003eG 3\/4\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCold water connection, hot water connection\u003c\/td\u003e  \u003ctd\u003eG 1\/2\u003c\/td\u003e  \u003ctd\u003eG 1\/2\u003c\/td\u003e  \u003ctd\u003eG 1\/2\u003c\/td\u003e  \u003ctd\u003eG 1\/2\u003c\/td\u003e  \u003ctd\u003eG 3\/4\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eGas connection\u003c\/td\u003e  \u003ctd\u003e20 mm\u003c\/td\u003e  \u003ctd\u003e20 mm\u003c\/td\u003e  \u003ctd\u003e20 mm\u003c\/td\u003e  \u003ctd\u003e20 mm\u003c\/td\u003e  \u003ctd\u003e20 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eAir connection, exhaust gas\u003c\/td\u003e  \u003ctd\u003e60\/100 mm\u003c\/td\u003e  \u003ctd\u003e60\/100 mm\u003c\/td\u003e  \u003ctd\u003e60\/100 mm\u003c\/td\u003e  \u003ctd\u003e80\/125 mm\u003c\/td\u003e  \u003ctd\u003e80\/125 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003eCE\u003c\/td\u003e  \u003ctd\u003e0063CU3910\u003c\/td\u003e  \u003ctd\u003e0063CU3910\u003c\/td\u003e  \u003ctd\u003e0063CU3910\u003c\/td\u003e  \u003ctd\u003e0063CU3910\u003c\/td\u003e  \u003ctd\u003e0063CU3910\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr\u003e  \u003ctd\u003ecategory\u003c\/td\u003e  \u003ctd\u003eII2N3P\u003c\/td\u003e  \u003ctd\u003eII2N3P\u003c\/td\u003e  \u003ctd\u003eII2N3P\u003c\/td\u003e  \u003ctd\u003eII2N3P\u003c\/td\u003e  \u003ctd\u003eI2N\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e","brand":"Vaillant","offers":[{"title":"VC \/ 20kW","offer_id":47856484417884,"sku":"0010039093","price":5379.63,"currency_code":"EUR","in_stock":true},{"title":"VC \/ 25kW","offer_id":47856484450652,"sku":"0010039094","price":5638.86,"currency_code":"EUR","in_stock":true},{"title":"VC \/ 30kW","offer_id":47856484483420,"sku":"0010022052","price":5883.84,"currency_code":"EUR","in_stock":true},{"title":"VC \/ 15kW","offer_id":47856484385116,"sku":"0010039092","price":5249.21,"currency_code":"EUR","in_stock":true},{"title":"VCW \/ 25\/36kW","offer_id":47872653918556,"sku":"0010022004","price":6181.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/brennwert-gastherme-vaillant-ecotec-exclusive-mit-moderner-technologie-4950913.png?v=1770693437","url":"https:\/\/si.gemashop.de\/hr\/products\/condensing-gas-boiler-vaillant-ecotec-exclusive-pump-0063cu3910-ii2n3p","provider":"GEMA Shop","version":"1.0","type":"link"}