The Atmos KC 35 S is a coal gasifier with a boiler heat output of 35 kW for heating systems using brown coal briquettes as the main fuel. With generator gasification, an extraction fan, and provision for buffer tank integration, it is designed for classic solid fuel operation in appropriately planned central heating systems.

Wichtigste Vorteile

35 kW boiler heat output for appropriately designed heating systems

Main fuel: lignite briquettes; log wood can be used as alternative fuel

Downdraft gasification with extraction fan for controlled solid fuel operation

Fachhandel für Heiztechnik

  • Technische Beratung für Heiztechnik & Systemkomponenten
  • Sichere Zahlung
  • Paket- oder Speditionsversand je nach Produktart

GPSR Information

Ime: Jaroslav Cankař a syn ATMOS

Adresa: elenského 487 294 21 Bělá pod Bezdězem, Cr

E-mail: info@atmos-zentrallager.de

Web stranica: https://www.atmos.eu/de/

Europski proizvođač: Da

Product Overview & Application

The Atmos KC 35 S coal gasifier is a manually fed hot water boiler with 35 kW rated heat output for heating systems designed to use lignite briquettes as the primary fuel. It is suitable for buildings with a corresponding heat demand and is typically integrated into a water-based central heating system with a buffer tank.

Dry split logs can be used as an alternative fuel. The boiler output, chimney, return temperature boost, and buffer tank should always be sized appropriately for the system.

Technology & Equipment

The boiler operates on the principle of downdraft gasification with an induced draft fan. The boiler casing is made of welded steel sheets, the lower secondary combustion chamber is lined with ceramic, and the air supply is managed via primary and secondary air inlets.

Standard equipment includes an electromechanical control unit, a Honeywell FR 124 draft regulator, a boiler thermostat, a flue gas thermostat, a safety thermostat, and a cooling coil to prevent overheating. The rotating grate mechanism supports operation with coal and wood as an alternative fuel.

Everyday Advantages

The Atmos KC 35 S is designed for practical, robust heating operation with manually fed solid fuel. The induced draft fan supports the combustion process and reduces smoke development in the operating area when refueling.

The combination of a ceramic-lined combustion chamber, preheated air supply, and mechanical grate technology makes this boiler appealing to operators seeking a classic solid fuel boiler with a clear technical design.

System Integration & Compatibility

Operation requires integration with a return temperature boost system to achieve the necessary return water temperature. The boiler outlet temperature during operation ranges from 80 to 90 °C.

Installation with a buffer tank is intended for system operation. Additionally, chimney draft, flue gas routing, combustion air supply, and safety components must be planned and executed to match the heating system.

Technical Specifications at a Glance

An overview of the key technical data for the Atmos KC 35 S.

Rated Output 35 kW
Fuel Lignite briquettes
Combustion Technology Downdraft gasification with induced draft fan
Efficiency 90.3 %
Energy Efficiency Class C
Max. Flow Temperature 90 °C
Max. Operating Pressure 2.5 bar
Log Length 330 mm
Boiler Class 5
Draft Requirement 24 Pa
Flue Gas Temperature 209 °C
Flue Pipe Connection 150/152 mm
Safety Heat Exchanger Cooling coil to prevent overheating included
Buffer Tank Recommended Yes
Height 1435 mm
Width 675 mm
Depth 758 mm
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W

Installation

Installation is carried out as part of a water-based heating system with a suitable return temperature boost, flue gas routing, combustion air supply, and safety equipment. The boiler is intended for placement in a suitable boiler room and requires coordinated integration with the chimney, buffer tank, and heating circuit.

Notes

The primary fuel is lignite briquettes. Dry split logs can be used as an alternative fuel. For consistently clean operation, fuel quality, chimney draft, return water temperature, regular cleaning, and professional commissioning are crucial.

Scope of Delivery

  • Atmos KC 35 S coal gasifier
  • Steel brush with accessories
  • Poker
  • Filling valve
  • Operating and maintenance manual
  • Honeywell FR 124 draft regulator
  • Ash container
HerstellerAtmos
ProdukttypCoal gasifier
ModellKC35S
MPN / Herstellernummer01.12.36
GTIN / EAN8595183306343
Förderstatusnot eligible for funding
Nennleistung35.0 kW
BrennstoffKohle
VerbrennungstechnikCoal gasifier
Wirkungsgrad87.6 %
EnergieeffizienzklasseC
Max. Vorlauftemperatur65.0 °C
Max. Betriebsdruck2.5 bar
Max. Scheitholzlänge330 mm
KesselklasseClass 5
Zugbedarf24 Pa
Abgastemperatur219 °C
Rauchrohranschluss150 mm
Empfohlenes Puffervolumen2000 l
Höhe1435 mm
Breite758 mm
Tiefe675 mm

Zu diesem Produkt wurden noch keine sauber darstellbaren produktspezifischen Fragen hinterlegt. Unser Fachteam unterstützt dich gerne bei technischen Fragen zur Auswahl, Montage oder Kompatibilität.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare