Nimi: Jaroslav Cankař a syn ATMOS
Osoite: elenského 487 294 21 Bělá pod Bezdězem, Cr
Sähköposti: info@atmos-zentrallager.de
Verkkosivusto: https://www.atmos.eu/de/
Eurooppalainen valmistaja: Kyllä
| Rated Output | 29,8 kW |
| Efficiency | 91,3 % |
| Energy Efficiency Class | A+ |
| Max Log Length | 530 mm |
| Boiler Class | 5 |
The Atmos DC30GSE wood gasification boiler is a manually fed log wood boiler from the ATMOS GSE series for central hot water heating systems. With a boiler output of 29.8 kW, it is suitable for buildings with a corresponding heat demand where log wood is used as fuel and the heat is integrated into the heating system via a suitably sized buffer tank.
The DC30GSE operates on the principle of wood gasification with reverse combustion. The boiler features a ceramic-lined combustion chamber, an induced draft fan, separately adjustable primary and secondary air, and electromechanical boiler control. A Belimo actuator is integrated into the boiler logic to limit the flue gas temperature. The standard design is intended for manual ignition.
The GSE design combines a robust steel boiler construction with practical operation for log wood firing. The large loading door makes refueling easier, the induced draft fan supports the combustion process, and the automatic shutdown after the wood has burned out contributes to orderly operation of the fan and boiler circulation pump.
The Atmos DC30GSE is designed for integration into a heating system with a sufficiently sized buffer tank. Proper hydraulic integration, return temperature boosting, and suitable chimney draft are important for operation. Planning should be tailored to the building, heat load, buffer volume, and existing heat distribution.
The key technical data of the Atmos DC30GSE based on the available manufacturer documentation.
| Nominal Output | 29.8 kW |
| Fuel | Log wood, dry |
| Combustion Technology | Wood gasification |
| Efficiency | 91.3 % |
| Energy Efficiency Class | A+ |
| Maximum Operating Pressure | 2.5 bar |
| Maximum Log Length | 530 mm |
| Boiler Class | 5 |
| Draft Requirement | 20 Pa |
| Flue Gas Temperature | 147.9 °C |
| Flue Pipe Connection | 150/152 mm |
| Safety Heat Exchanger | present |
| Buffer Tank Recommended | yes |
| Ignition System | manual |
| Height | 1281 mm |
| Width | 680 mm |
| Depth | 1020 mm |
| Weight | 466 kg |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Power Consumption | 50 W |
Installation and integration of the boiler should be carried out by a qualified specialist company. For operation, a suitable chimney, return temperature boosting with a minimum return temperature of 65 °C, and a sufficiently sized buffer tank must be considered. The electrical connection is made to 230 V / 50 Hz.
Dry log wood with a moisture content of 12 to 20 % is intended for operation. The boiler operates in non-condensing mode and is designed for a boiler temperature in the range of 80 to 90 °C. Operation, cleaning, maintenance, and commissioning should be carried out according to the manufacturer's documentation.
Payment options
Your payment information is processed securely. We do not store or access your credit card information.